3 — ONT and MDU general and interface technical specifications
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a March 2011 3-19
3FE 54199 AAAA TCZZA Edition 01 ONT Product Information Guide
The power can be supplied by the ONT or MDU. In the ONT PoE case, jumpers must
be configured on the EPC interface of the ONT to enable +12V power. In the MDU
case, when the video return channel is configured for the SWRD Ethernet port,
power is available.
Table 3-10 lists the electrical specifications for the SWRD when all ports and cabling
use IEEE 802.3-compliant materials.
Table 3-10 SWRD electrical specifications
The environmental specifications of the SWRD are as follows
operating temperature range is –40°F to 140°F (-40°C to 60°C) and to the
equivalent of 105.8°F (41°C) with solar loading
operating relative humidity is 5% to 95%, non-condensing
operating altitude range is 200 ft (61 m) below mean sea level to 13 000 ft (3962
m) above mean sea level
operating temperature can vary by 3°F (16.6°C) per minute, to the maximum and
minimum ranges
The physical specifications of the SWRD are as follows
housing dimensions: 6.78 in. wide by 1.29 in. deep by 5.77 in. high (17.45 cm by
3.38 cm by 14.66 cm)
weight: 1.5 lb (0.68 kg)
3.9 RSSI specifications
Received signal strength indication (RSSI) is a measurement of radio signal strength
at the receiver. Use of the RSSI metric is governed by the IEEE 802.11 standard,
which does not define any relationship between RSSI value and power level in mW
or dBm. RSSI measurements are specified without units and range in value from 0
to 255 with the highest value being referred to as RSSI Max. Defining RSSI values
or power levels is the responsibility of the vendor.
According to the Alcatel-Lucent implementation of RSSI for ONTs, the RSSI value
is expressed in power levels of dBm and is the measurement of the received optical
signal level at 1490 nm in dBM. The RSSI range is -65.536 to +65.534. The absolute
accuracy of the optical signal reading is +/-3.0 dB. Take this possible variation in
measured signals into account when reading the metric values.
Electrical specifications Value
Surge resistance on Ethernet ports 1.5 kV (1 positive, 1 negative)
Surge resistance on RF ports 1.5 kV (1 positive, 1 negative)
Forward pass band 46 to 870 MHz
Reverse operating frequency 18.5 MHz
Maximum length of power supply
coaxial cable
50 ft (15.24 m)