6 —  ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a March 2011 6-33
3FE 54199 AAAA TCZZA Edition 01 ONT Product Information Guide
Procedure 6-19  To check the status of LEDs
1 From the Web-Management System window, click on the States Management 
tab, as shown in Figure 6-15. 
Figure 6-15  Main options in Web-Management system window
The ONT status window opens with the ONT states and their current status, as 
shown in Figure 6-10.
2 Click on the LED tab. The ONT LEDs window appears with the LEDS, their color, 
current LED state, and persistent LED state shown.
Figure 6-16  ONT LEDs
where
LED is the mnemonic for an LED on the ONT. Each LED represents a condition or activity on the 
ONT, such as the condition of the battery or the activity of a data link; see Table 6-7 for an 
explanation of each LED.
COLOR is the color of the LED. The color of the LED represents the status of a condition or activity 
on the ONT, such as red for failing battery or green for activity on the data link; see the 
ONT-specific unit data sheet for the meaning of a color for a specific LED and ONT type.
CURSTATE represents the current LED state, where OFF means the LED is not lit, ON means that 
the LED is lit and the color is solid.
PERSTATE represents the persistent state of the LED, where OFF means that the LED was not lit, 
and ON means that the LED was lit and the color was solid.
3 Use the scroll bar in the ONT LEDs window to scroll up and down the list of LEDs.
4 Click on the Refresh button to refresh the contents of the window.
5 STOP. This procedure is complete.