6 — ONT management using an ONT interface
6-26 March 2011 Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
ONT Product Information Guide Edition 01 3FE 54199 AAAA TCZZA
2 Use the scroll bar in the ONT status window to scroll up and down the list of ONT
states.
3 Click on the Refresh button to refresh the contents of the window.
4 STOP. This procedure is complete.
Procedures using CLI interface
The following procedure provides the steps to check ONT status using the CLI
interface.
Procedure 6-14 To check ONT status
1 Choose option 8, More options, from the Main menu. The Secondary menu
appears.
2 Choose option 2, Retrieve ONT states, from the secondary menu.
The list of ONT states appear with their current status shown as either active or
inactive. For example:
ONT_SW_FAULT -- INACTIVE
OMCI_ENV1 -- INACTIVE
OMCI_ENV2 -- INACTIVE
NO_ALARM -- INACTIVE
press enter key to continue...
where
the ONT state is shown as a mnemonic that represents a possible condition on the ONT; see
Table 6-6 for an alphabetical listing and description of the ONT states
the operational state of the condition is either active, which means that the condition is present
on the ONT, or inactive, which means that the condition is not present on the ONT
3 Press to continue.
4 Choose option 11, Return to main menu, to return to main menu.
5 STOP. This procedure is complete.
Procedures using HTTP interface for Package C ONTs
Not applicable.
Procedures using CLI interface for Package C ONTs
Not applicable.