6 — ONT management using an ONT interface
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a March 2011 6-61
3FE 54199 AAAA TCZZA Edition 01 ONT Product Information Guide
Procedure 6-42 To clear the SLID
1 Perform one of the following:
a If you are using an Ethernet port, ensure that the ONT is disconnected from
the PON optical cable.
b If you are using a craft port, you can clear the SLID with the ONT connected
to or disconnected from the PON optical cable.
2 Choose option 5, Clear SLID, from the Main menu to clear the SLID.
The ONT sets the SLID to the default value, and the following message appears:
SLID cleared successfully!
3 Choose option 4, Retrieve SLID from the main menu to verify that the SLID is reset
to its default value.
4 STOP. This procedure is complete.
Procedure 6-43 To enter the SLID
1 Perform one of the following:
a If you are using an Ethernet port, ensure that the ONT is disconnected from
the PON optical cable.
b If you are using a craft port, you can enter the SLID with the ONT connected
or disconnected from the PON optical cable.
2 Choose option 4, Retrieve SLID, from the Main menu to ensure that the SLID is set
to DEFAULT or null.
3 Perform one of the following from the main menu
a Choose option 1, Enter SLID in volatile mode, to enter a volatile SLID.
b Choose option 2, Enter SLID in permanent mode, to enter a non-volatile
SLID delivered in proprietary mode.
c Choose option 3, Enter SLID in registration mode, to enter a non-volatile
SLID delivered in registration ID mode.
The following appears:
Enter Subscriber Location Id
> ALPHANUMERIC MODE (Length(1..10)):
> HEX MODE (Length(1..20))
> Note: FOR HEX MODE -- APPEND THE VALUE WITH 0x