3.4. 
SIP registration 
 
In order to perform SIP registration, some parameters are mandatory in the sipconfig-mac@.txt 
file:
 
 
authentication_realm=
 
authentication_name=
 
authentication_password=
 
proxy_addr=
 
registrar_addr=
 
 
Refer to SIP configuration files description. 
3.5. 
Updating SIP binaries
 
To update SIP binaries on an IP Touch 40x8EE phone, SIP binaries must be made available on the 
server  as  indicated  in  SIP  binary  files,  and the  set  must  reset.  This  can  be  done  manually  and 
automatically. 
–  Manually: 
by disconnecting the power cable of the set and plugging it in again.  
–  Automatically: 
the set will reset by itself after a polling timer defined in the configuration file (field Binary 
polling timer) registered in the set at first initialization. The set monitors the server to check 
if  new  binary  files  are  available.  When  there  are  new  binary  files,  the  set  automatically 
restarts and proceeds with a binary update.  
After user changes any parameters in admin settings and exits, phone will reset automatically.