MicrowaveradiorelaylinkZENITH80
38/52 1.2
Figure24 Pointing
Figure25 Radiationdiagram
The pointing procedure in both horizontal and vertical directions must be repeated several times to
makesurethatthebestmaximumoftheradiationcharacteristicwasfound.Theoppositestationantenna
needstobefinaladjustedthesameway.
CheckingofPointing
ThevalueofreceivedlevelcanbedeterminedbydirectreadingintheASDmonitoringprogramorby
calculation using the calibration graph for RSSI. The RSSI voltage can be measured at the BNC connector
withoutnecessitytoadjusttherotaryswitch.
Tocheckfortheproperpointing,itisgood
tocalculatethesignallevelthatshouldbemeasured.The
maximum allowed deviation between the calculated and measured signal levels is ±3 dB. If the negative
deviation is higher the connection needs to be better pointed. Control calculation is described in chapter
4.2onpage40.
The noise level on
the receiving channel needs to be checked while the opposite station is switched
off.Theminimum requestedseparation of thenoiselevelfromthe received signalis20dB.The opposite
stationcanbeswitchedoffremotelyusingtheASDmonitoringprogram.
• Whilewrongpointinginonedirection(e.g.vertical)onlysidelobesmaybefoundinthe
seconddirection.
• Pointing toside lobe isa commonmistake. You may find sharmmacximum, buttheRx
levelis13dBlower.
• Werecommendfindingmainlobeandbothsidelobesduringthefirstpointingstep.