Fuel Tank Inlet Filter
WARNING: Ensure the engine is switched off while undertaking this task.
1. Turn the fuel tap/ lever (26) to the off position (Fig AC).
3. The fuel tank inlet filter (27) is located directly under the fuel tank cap
(2) and protects impurities entering the fuel tank (1) during refuelling.
Remove the fuel tank cap (2) by turning in an anti-clockwise direction
(Fig AD).
4. Remove the fuel tank inletlter (27) (Fig AE) and wash thoroughly in
petrol.
5. Re-assemble by putting the fuel tank inlet filter (27) back, and then
securing the fuel tank cap (2) in a clockwise direction until firmly secured
Maintenance
AE.AD.
AC.
ON
OFF