5 Operating Instructions 5.2 Normal operation
3.
Ensure that the separator is at full speed.
The time by full speed can be checked by
studying the ammeter.
- Current increases during start (1).
- When full speed has been reached, the current
decreases to a stable value (2).
For normal length of the start-up period, see 8.2
Technical data on page 179.
R
O
I
1
2
G0871931
4.
Perform a “discharge” to fill up the operating
water system.
a.
Add opening water until a discharge sound
is heard (10 seconds).
b. Wait 15 seconds.
c.
Add closing water for 15 seconds.
5.
Add some hot conditioning water.
6.
Turn on the oil feed.
N
O
T
E
Before turning on the feed make su re that th e oil has
the correct temperature .
35