7 Fault Finding
These fault finding instructions are for the separator only. If a fault occurs, study the System
Documentation fault finding section (if applicable).
7.1 Mechanical Functions
7.1.1 Separator vibratio n
!
W
A
R
N
I
N
G
Disintegration hazards
If excessive vibration occurs, stop separator an d keep
bowl filled with liquid during rundown.
The cause of the vibration must be identified and
corrected before the separator is restarted.
N
O
T
E
Some vibration is normal during the starting and
stopping sequences when the separator passes
through its critical s peed.
Cause Corrective action
Bowl out of balance due to:
- poor cleaning
- incorrect assembly
- incorrect disc stack compression
- bowl assembled with parts from other
separators
Dismantle the separator and check the assembly
and cleaning.
Uneven sludge deposits in the sludge space. Dismantle and clean the separator bowl.
Height position of paring disc is incorrect.
Stop the separator, measure, and if necessary,
adjust the height.
Bowl spindle bent. Renew the bowl spindle.
Bearing(s) damaged or worn.
Renew all bearings.
Th
e frame feet are worn out.
Re
new the frame feet.
Spindle top bearing spring broken.
Renew all springs.
171

Related product manuals