8128 SIP Strobe Light (G2)
Basic Settings Tab – Multicast (Master Settings)
Multicast Mode (Master/Sender Selected)
If master is enabled the 8128 SIP will broadcast an IP stream when activated and
flash a light pattern.
Multicast Type – Regular
Select ‘Regular (RTP)’ if solely multicasting to Algo SIP endpoint(s) and/or
multicast enabled phone(s) that use RTP audio packets.
Number of Zones
Select “Basic Zones Only” if configuring nine or fewer multicast zones (shown
beside “Speaker Playback Zones”) or select “Basic and Expanded Zones” to
configure up to 50 zones. The expanded zones have the same behavior as the
basic Slave zones, but are hidden by default to simplify the interface.