8128 SIP Strobe Light (G2)
Advanced Settings Tab – Advanced Multicast
The default prepopulated multicast addresses above will work in most cases and
should only be altered for rare cases.
RTCP Port Selection
Select the port on which RTCP packets will be sent or received. If using the 'Next
Higher Port' option, ensure that the default multicast zone definitions are modified
such that zones are only assigned to even-numbered ports, leaving the next
higher odd-numbered ports free for RTCP packets.
Zone Definition
The “Expanded” Slave or Master zones can be enabled/disabled in Basic Settings
> Multicast. Default IP addresses and ports may be revised for any given zone in
the table.
Important: Ensure that the Address and Port settings are the same for all master
and slave devices.
Strobe Pattern
When the 8128 Strobe Light is the multicast Slave, a strobe pattern will flash each
time a multicast stream is detected.
By default, the same flash pattern can be set for all Slave zones in the Basic
Settings > Features tab. Unique flash patterns may be revised on a per-zone basis
Document 90-00100C
11/27/2019
Page 47
Algo Communication Products Ltd
4500 Beedie St Burnaby BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792