8128 SIP Strobe Light (G2)
DO NOT LOOK DIRECTLY
Do not look directly at the 8128 SIP Strobe Light while operating in close proximity,
as vision may be affected. The LEDs in the 8128 light are classified according to
the IEC 62471-2006 standard as “RG-1” for risk group 1. This is defined as “Low
risk. No photobiological hazard under normal behavioral limitations.”
PHOTO-SENSITIVITY
Photo-sensitivity in some people with epilepsy can trigger seizures from flashing or
flickering lights. It is possible that some flash patterns of the 8128 SIP Strobe Light
could trigger a seizure for some individuals under some conditions. High intensity
patterns should only be selected if necessary for the 8128 to be effective.
WET OR OUTDOOR ENVIRONMENTS
The 8128 SIP Strobe Light is intended for indoor or outdoor locations and may be
subjected to spray or weather provided the rear wiring cavity is properly sealed to
prevent water ingress.
Gaskets included with the 8128 SIP Strobe Light may be effective against water
ingress on some, but not all surfaces in which case additional protective measures
must be taken such as a perimeter sealant.
CAT5 or CAT6 connection wiring to an IEEE 802.3at PoE+ or 802.3af compliant
network PoE switch must not leave the building perimeter without adequate
lightning protection.
No wiring connected to the 8128 SIP Strobe Light may leave the building
perimeter without adequate lightning protection.