198 Math Instructions
Special Considerations when Using Floating Point Parameters
If any of the parameters (except Output) are NAN (not a number),
Infinity, or De-normalized; then the result is -NAN.
If y
1
- y
0
or x
1
- x
0
result in an overflow, then the result is -NAN
Other Considerations
If y
1
- y
0
= 0, the Result becomes the Scaled Start value
If x
1
- x
0
= 0 and x = x
0
, the Result becomes the Scaled Start value
If x
1
- x
0
= 0 and x does not equal x
0
, The Result becomes a negative
overflow (for integer values) or a negative NAN (for floating point values)
SCP Instruction Valid Addressing Modes and File Types
For definitions of the terms used in this table see Using the Instruction Descriptions on page 82.
Parameter
Data Files
Function Files
(1)
CS - Comms
IOS - I/O
DLS - Data Log
Address
Mode
(2)
Address Level
O
I
S
B
T, C, R
N
F
ST
L
MG, PD
RI/RIX
PLS
RTC
HSC
PTO, PWM
STI
EII
BHI
MMI
LCD
Immediate
Direct
Indirect
Bit
Word
Long Word
Element
Input (x) ••••••• ••• •••••••••• • •••
Input Min. (x
0
)
•• •••• • •
• • •••
Input Max. (x
1
)
•• •••• • •
• • •••
Scaled Min. (y
0
)
•• •••• • •
• • •••
Scaled Max. (y
1
)
•• •••• • •
• • •••
Output (y) ••••••• ••• • ••• •
• •••
(1) PTO and PWM files are only for use with MicroLogix 1100 BBB unit.
(2) See Important note about indirect addressing.
IMPORTANT
You cannot use indirect addressing with: S, ST, MG, PD,
RTC, HSC, PTO, PWM, STI, EII, BHI, MMI, CS, IOS, and
DLS files.
IMPORTANT
Do not use the High Speed Counter Accumulator
(HSC.ACC) for the Scaled Output parameter in the SCP
instruction.
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1763-L16BWA and is the answer not in the manual?

Allen-Bradley 1763-L16BWA Specifications

General IconGeneral
BrandAllen-Bradley
Model1763-L16BWA
CategoryController
LanguageEnglish

Related product manuals