Publication 1763-RM001C-EN-P - October 2009
562 Knowledgebase Quick Starts
Using the Data Logging Utility Software to recover data
The Data Logging utility is the only supported method for
retrieving data, that has been stored in the processor.
1. Install the DLOG utility (found at
http://www.ab.com/plclogic/
micrologix/)
2. Execute DLCA1764.EXE
3. Configure Port, Baud Rate, and DF1 Node as shown below.
4. Click “Connect”.
FYI - By default the MicroLogix 1100 communications are
configured for 19200 baud If using defaults select 19200 above,
otherwise select the baud rate configured in the MicroLogix Channel
Configuration Screen.
If a correct configuration has been selected the utility software will
indicate that it has connected to the processor as shown below.
ATTENTION
!
If any other software package, such as RSLINX has
control of the computers communication port or if the
wrong COM port is selected or a processor other then
the MicroLogix 1100 is connected to the computer you
will not be able to continue.
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1763-L16BWA and is the answer not in the manual?

Allen-Bradley 1763-L16BWA Specifications

General IconGeneral
BrandAllen-Bradley
Model1763-L16BWA
CategoryController
LanguageEnglish

Related product manuals