9 Publication 1762-RM001C-EN-P
MicroLogix 1200 and 1500
Alphabetical List of Instructions
Instruction- Description Page Instruction- Description Page
ABL - Test Buffer for Line 20-14 MCR - Master Control Reset 16-5
ACB - Number of Characters in Buffer 20-15 MEQ - Mask Compare for Equal 9-6
ACI - String to Integer 20-16 MOV - Move 13-1
ACL - ASCII Clear Buffers 20-7 MSG - Message 21-3
ACN - String Concatenate 20-18 MUL - Multiply 10-5
ADD - Add 10-4 MVM - Masked Move 13-3
AEX - String Extract 20-19 NEG - Negate 10-6
AHL - ASCII Handshake Lines 20-20 NEQ - Not Equal 9-3
AIC - ASCII Integer to String 20-8 NOT - Logical NOT 12-6
AND - Bit-Wise AND 12-3 ONS - One Shot 7-5
ARD - ASCII Read Characters 20-22 OR - Logical OR 12-4
ARL - ASCII Read Line 20-23 OSF - One Shot Falling 7-6
ASC - String Search 20-25 OSR - One Shot Rising 7-6
ASR - ASCII String Compare 20-26 OTE - Output Energize 7-3
AWA - ASCII Write with Append 20-9 OTL - Output Latch 7-4
AWT - ASCII Write 20-11 OTU - Output Unlatch 7-4
BSL - Bit Shift Left 14-4 PID - Proportional Integral Derivative 19-3
BSR - Bit Shift Right 14-6 PTO - Pulse Train Output 6-1
CLR - Clear 10-6 PWM - Pulse Width Modulation 6-18
COP - Copy File 14-2 RAC - Reset Accumulated Value 5-27
CTD - Count Down 8-9 REF- I/O Refresh 17-4
CTU - Count Up 8-9 RES - Reset 8-10
DCD - Decode 4 to 1-of-16 11-2 RET - Return from Subroutine 16-3
DIV - Divide 10-5 RTO - Retentive Timer, On-Delay 8-6
DLG - Data Log Instruction 22-8 SBR - Subroutine Label 16-3
ENC - Encode 1-of-16 to 4 11-3 SCL - Scale 10-7
END - Program End 16-5 SCP - Scale with Parameters 10-8
EQU - Equal 9-3 SQC- Sequencer Compare 15-2
FFL - First In, First Out (FIFO) Load 14-8 SQL - Sequencer Load 15-8
FFU - First In, First Out (FIFO) Unload 14-11 SQO- Sequencer Output 15-5
FLL - Fill File 14-3 SQR - Square Root 10-9
FRD - Convert from Binary Coded Decimal (BCD) 11-4 STS - Selectable Timed Start 18-8
GEQ - Greater Than or Equal To 9-5 SUB - Subtract 10-4
GRT - Greater Than 9-4 SUS - Suspend 16-4
HSL - High-Speed Counter Load 5-26 SWP - Swap 10-10
IIM - Immediate Input with Mask 17-1 TND - Temporary End 16-4
INT - Interrupt Subroutine 18-7 TOD - Convert to Binary Coded Decimal (BCD) 11-8
IOM - Immediate Output with Mask 17-3 TOF - Timer, Off-Delay 8-5
JMP - Jump to Label 16-1 TON - Timer, On-Delay 8-4
JSR - Jump to Subroutine 16-2 UID - User Interrupt Disable 18-9
LBL - Label 16-2 UIE - User Interrupt Enable 18-10
LEQ - Less Than or Equal To 9-5 UIF - User Interrupt Flush 18-11
LES - Less Than 9-4 XIC - Examine if Closed 7-1
LFL - Last In, First Out (LIFO) Load 14-14 XIO - Examine if Open 7-1
LFU - Last In, First Out (LIFO) Unload 14-17 XOR - Exclusive OR 12-5
LIM - Limit Test 9-7

Table of Contents