Rockwell Automation Publication 520-UM001A-EN-E - February 2013 93
Programming and Parameters Chapter 3
Logic Group (continued)
L190 [Stp Logic Time 0]
L192 [Stp Logic Time 2]
L194 [Stp Logic Time 4]
L196 [Stp Logic Time 6]
L191 [Stp Logic Time 1]
L193 [Stp Logic Time 3]
L195 [Stp Logic Time 5]
L197 [Stp Logic Time 7]
Sets the time to remain in each step if the corresponding command word is set to “Step based on time.
Values Default: 30.0 s
Min/Max: 0.0/999.9 s
Display: 0.1 s
L200 [Step Units 0]
L204 [Step Units 2]
L208 [Step Units 4]
L212 [Step Units 6]
L202 [Step Units 1]
L206 [Step Units 3]
L210 [Step Units 5]
L214 [Step Units 7]
32 bit parameter.
Sets the position in user-defined units the drive must reach at each step.
Values Default: 0
Min/Max: 0/6400
Display: 1