PowerFlex 700 Adjustable Frequency AC Drive Quick Start 21
SPEED COMMAND
Spd Mode & Limits
079 [Speed Units]
Selects the units to be used for all speed
related parameters. Options 0 & 1
indicate status only. Options 3 & 4 will
convert/configure the drive.
“Convert Hz” - converts all speed based
parameters to Hz, and changes the value
proportionately (i.e. 1800 RPM = 60 Hz).
“Convert RPM” - converts all speed
based parameters to RPM, and changes
the value proportionately.
Default:
Options:
0
0
1
2
3
“Hz”
“Hz”
“RPM”
“Convert Hz”
“Convert RPM”
080 [Speed Mode]
Sets the method of speed regulation.
Default:
Options:
0
0
1
2
“Open Loop”
“Open Loop”
“Slip Comp”
“Process PI”
[Feedback Select]
Selects the source for motor speed
feedback.
“Open Loop” - no encoder is present, and
slip compensation is not needed.
“Slip Comp” - tight speed control is
needed, and encoder is not present.
“Encoder” - an encoder is present.
“Simulator” - Simulates a motor for test-
ing drive operation & interface checkout.
Default:
Options:
0
0
1
2
3
4
5
“Open Loop”
“Open Loop”
“Slip Comp”
“Reserved”
“Encoder”
“Reserved”
“Simulator”
081 [Minimum Speed]
Sets the low limit for speed reference
after scaling is applied. Refer to
parameter 083 [Overspeed Limit].
Default:
Min/Max:
Units:
0.0
0.0/[Maximum Speed]
0.1 Hz
0.1 RPM
079
083
092
095
082 [Maximum Speed]
Sets the high limit for speed reference
after scaling is applied. Refer to
parameter 083 [Overspeed Limit].
Default:
Min/Max:
Units:
50.0 or 60.0 Hz (volt class)
[Motor NP RPM]
5.0/400.0 Hz
5.0/400.0 Hz
0.0/24000.0 RPM
0.1 Hz
0.1 RPM
055
079
083
091
094
202
Speed Reference
090 [Speed Ref A Sel]
Selects the source of the speed
reference to the drive unless [Speed Ref
B Sel] or [Preset Speed 1-7] is selected.
(1)
See User Manual for DPI port
locations.
Default:
Options:
2
1
2
3-6
7
8
9
10
11-
17
18-
22
“Analog In 2”
“Analog In 1”
“Analog In 2”
“Reserved”
“Pulse In”
“Encoder”
“MOP Level”
“Reserved”
“Preset Spd1-7”
“DPI Port 1-5”
(1)
002
091
thru
093
101
thru
107
117
thru
120
192
File
Group
No.
Parameter Name & Description Values
Related
Vector
Standard
Vector
Vector
Vector
Vector
Vector

Other manuals for Allen-Bradley powerflex 700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley powerflex 700 and is the answer not in the manual?

Allen-Bradley powerflex 700 Specifications

General IconGeneral
SeriesPowerFlex 700
CategoryAC Drive
Input Voltage200-240V AC, 380-480V AC, 500-600V AC
EnclosureType 1
Control MethodSensorless Vector
CommunicationEtherNet/IP, ControlNet, DeviceNet, PROFIBUS DP, Modbus

Related product manuals