148 Rockwell Automation Publication 750COM-UM009A-EN-P - May 2017
Appendix D EtherNet/IP Objects
13 Get DPI Read Basic STRUCT of:
BOOL[32]
CONTAINER
CONTAINER
CONTAINER
CONTAINER
STRING[16]
STRING[4]
Descriptor (see page 150
)
Parameter value
Minimum value
Maximum value
Default value
Parameter name
Units (for example, Amps, Hz)
14 Get DPI Parameter
Name
STRING[16] Parameter name
15 Get DPI Parameter Alias STRING[16] Customer-supplied parameter name.
16 Get Parameter
Processing Error
USINT 0 = No error
1 = Value is less than the minimum
2 = Value is greater than the maximum
18 Get International DPI
Offline Parameter
Tex t
Struct of:
STRINGN
STRINGN
International parameter name
International offline units
19 Get International DPI
Online Parameter
Tex t
Struct of:
STRINGN
STRINGN
International parameter name
International online units
Table 51 - DPI Parameter Object: Instance Attributes (continued)
Attribute ID Access
Rule
Name Data Type Description

Table of Contents