Error Codes
Display Description Cause/ Corrective Action
Eg 01
ICM Lockout Alarm Active Check that the gas is turned on and that the
ignition circuit functions. Also check that
the gas valve is operational. This error
needs to be manually reset. To reset, open
service door and press start button. After 5
seconds error should be cleared.
Eg 02
ICM Alarm Reset Shorted Error Check wiring between the I/O board and
the ignition control. Power down and pow-
er up machine to clear the error.
Eg 03
ICM Hardware Failure Error Ignition control has detected a hardware
fault. Power down and power machine to
clear error. Replace ignition control if error
persists.
Eo 05
I/O Board 24VDC Supply Over Voltage
Error
Check machine input voltage. Power down
and power up the machine to clear error. If
error persists, replace I/O board.
Eo 06
I/O Board 24VDC Supply Under Voltage
Error
Check machine input voltage. Check for
pinched control wires. Clear any debris or
lint from the I/O board. Power down and
power up the machine to clear error. If er-
ror persists, replace I/O board.
Eo 07
Heat Output Shorted Error Power down machine to clear error, power
up machine, try heating again. If error per-
sists, replace I/O board.
Eo 32
Mosfet Enabled Shorted Error Power down machine to clear error, power
up machine, try running a cycle. If error
persists, replace I/O board.
EN rL
Manual Reset Limit Error Inspect tumble dryers venting/ventwork to
ensure that the ventwork is adequate and
that there are no blockages. Be sure to
clean and inspect lint screen. Remove any
lint buildup around the thermostat. Limit
needs to be manually reset and machine
needs to be powered down to clear the er-
ror. If problem persists, replace thermostat.
ES L1
Stove Limit 1 Cycle Inspect tumble dryers venting/ventwork to
ensure that the ventwork is adequate and
that there are no blockages. Be sure to
clean and inspect lint screen. Remove any
lint buildup around the thermostat. If prob-
lem persists, replace thermostat.
Table 9  continues...