Regulated Natural Gas machines and convert according to Table
1 .
CE Orifices
Gas
Type
Gas
Family Group
Gas
Designation
Supply
Pressure
in. wc
(mbar, kPa)
Manifold
Pressure
in. wc
(mbar, kPa)
Capacity/
Model
Orifice
Diameter
inch
(mm)
Orifice
Part
Number Quantity
120 0.1695
(4.3)
M402988 3
170 0.1850
(4.7)
M411510 4
I
2H(E)
G20 8/10
(20/25, 2/2.5)
3.57
(8.9, 0.89)
200 0.1890
(4.8)
M411372 4
120 0.1695
(4.3)
M411373 3
170 0.1850
(4.7)
M411510 4
I
2L
G25 10 (25, 2.5) 5.06
(12.6, 1.26)
200 0.1890
(4.8)
M411372 4
120 0.1417
(3.6)
M401014 3
170 0.1496
(3.8)
M402997 4
Natural
Gas
Second
I
2E+
G20 8 (20, 2.0) Unregulated
200 0.1520
(3.9)
M401020 4
120 0.0980
(2.5)
M406361 3
170 0.1200
(3.0)
M401017 3
LP Third I
3B/P
G30 11.25/12
(28/30, 2.8/3.0)
Unregulated
200 0.1220
(3.1)
70070903 3