Gas Requirements
52
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR7
Altitude Orifice New Rate
Model Gas feet (m) No. inches (mm) Quantity Part No.
Btu/hr.*
(Mj/hr.)
2,001 – 4,000
(610 – 1,220 )
1/8 0.1250 (3.2) M402489 363,400
(383)
4,001 – 6,000
(1,221 – 1,830)
31 0.1200 (3) M401017 331,800
(350)
6,001 – 8,000
(1,831 – 2,440)
32 0.1160 (2.9) M402444 300,200
(317)
L.P. Gas
8,001 – 10,000
(2,441 – 3,050)
34 0.1110 (2.8)
3
M411512 268,600
(283)
2,001 – 4,000
(610 – 1,220)
12 0.1890 (4.8) M411372 391,000
(413)
4,001 – 6,000
(1,221 – 1,830)
14 0.1820 (4.6) M411371 357,000
(377)
6,001 – 8,000
(1,831 – 2,440)
17 0.1730 (4.4) M411374 323,000
(341)
Natural Gas
8,001 – 10,000
(2,441 – 3,050)
19 0.1660 (4.2)
4
M402995 289,000
(305)
2,001 – 4,000
(610 – 1,220)
30 0.1285 (—) M401021 391,000
(413)
4,001 – 6,000
(1,221 – 1,830)
1/8 0.1250 (3.2) M402489 357,000
(377)
6,001 – 8,000
(1,831 – 2,440)
31 0.1200 (3) M401017 323,000
(341)
200L/N
L.P. Gas
8,001 – 10,000
(2,441 – 3,050)
33 0.1130 (2.9)
3
M401022 289,000
(305)
*Btu/hr. derate of 4% per 1,000 ft. (305 m) of altitude.
Table 6

Table of Contents

Other manuals for Alliance Laundry Systems CA120L