Electrical Requirements
Part No. 70458101ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 57
on power lines to the machine. Failure to properly install the ferrite ring may result in damage to the electronic controls
and will void control warranty.
To install:
1. Immediately after connection of power leads and before
applying power to machine, locate each of the incoming
service leads including ground.
2. Snap the ferrite ring closed over all the service leads inside
of the contactor box as shown. It is important that the ferrite
ring be installed inside the contactor box. Refer to Figure
20 . Do not install the ferrite outside of the box or other
area. Make sure that service leads are in the center of the
ferrite before closing the ring so as not to pinch or damage
leads.