102 801683
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
46. GRAVITY DRAIN VALVE
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel. Refer to Figure 41.
b. Gently lower access panel to disengage panel
locators from bottom edge of front panel.
c. Loosen hose clamps and remove tub-to-drain
and drain-to-cabinet hoses connected to drain
valve. Refer to Figure 44.
d. Disconnect wires from drain valve.
NOTE: Refer to wiring diagram when rewiring
drain pump.
e. Remove screws holding valve to bracket and
remove valve through front of washer. Refer to
Figure 44.
Figure 44
FLW1685S
Tub-to-Drain
Hose
Bracket
Drain-to-Cabinet
Hose
Drain
Valve