Loading...
20 801683
Section 3 Troubleshooting (Electromechanical Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5. WASHER WILL NOT START – NO LEDS/LIGHTS LIT
(No Response to Start Switch)
Is there 120 VAC
to control
Transformer?
(2)
(3)
No
Yes
Yes
Is there
continuity across
"H3-1" and "H3-2" on
the machine control when
the coin slide is
pushed in?
Replace machine
control.
No
Yes
(1)
Is there 24 VAC
from "H1-1" to "H1-3"
on the machine control ?
Replace
transformer.
Check wiring
to transformer.
No
Is there
continuity across
"H9-3" to "H9-7" on
the machine control when
the start switch is
depressed?
(4)
Correct wiring
to and/or replace
start switch.
Check wiring
between
coin slide switch
and machine
control.
No
Yes
FLW1725S