28 801683
Section 3 Troubleshooting (Electromechanical Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9. WASHER WILL NOT FILL
(In Use/Door Locked LEDs Flashing)
Is there
120 Volts at
terminals "H9-4" and
"H1-1" on the
motor control
board?
Replace
pressure
switch.
No No
Is there
120 Volts at
terminals "H9-1" to
"H1-1" on the motor
control board?
Yes
(1) (2)
(3)
Yes
Replace
pressure
switch.
Correct wiring
between machine
control and
pressure switch.
Yes
No
No
Replace
motor
control.
Replace mixing
valve.
(4)
Is there
120 Volts
at the
mixing valve?
Is there
120 Volts between
the BRN/YEL wire on the
pressure switch and
"H6-5" on machine
control?
Is the door
locked?
Refer to section:
Washer Will Not Start -
No Door Lock .
No
Yes
Yes
FLW1713S