Section 3 Troubleshooting (Electromechanical Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
8. MOTOR WILL NOT RUN
(Door Locked/Final Spin and Tumble LEDs Flashing)
(1)
No
Is there
continuity between
motor terminals?
Refer to values
at right.
Yes
Replace motor
control.
Replace motor.
FLW1712S
Motor Resistance Values:
Tach. Circuit: Approx. 115 ohms (Terminals 4-5)
Windings: Approx. 4 - 5 ohms (Terminals 1-2, 1-3, 2-3)