104 801683
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
48. MIXING VALVE
a. Front Control Washers –
(1) Remove control panel. Refer to Paragraph
30 or 32.
(2) Remove two screws holding front of
cabinet top to top front edge of control
cabinet front. Refer to Figure 22.
Rear Control Washers –
(1) While supporting lower front access panel,
remove two screws from bottom edge of
panel and remove panel. Refer to
Figure 25.
(2) Using the special tool, No. 318P4, remove
dispenser drawer. Refer to Figure 26.
Figure 45
Motor
Mounting
Bracket
Inner
Basket
Pulley
Pivot
Bolt
Adjusting
Bolt
Metal
Rod
Wire
Harness
1/4
Inch
Motor
Shaft
Belt
Adjusting
Bolt
Pivot
Bolt