Installation
15
512680
Figure 7
Figure 8
D686I
1 NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening must be
sized per local codes.
3 2 in. (5 cm) Minimum or Clearance per Local
Codes
4 No Screen or Cap
2 Wall 5 Clean Out Cover
Inspect Monthly
D686I
2
3
4
EXHAUST
OUTLET
KJIHGFEDCBA
5
30°
1
24 in. (61 cm)
MINIMUM
CLEARANCE TO
ROOF/GROUND
EXHAUST AIR FLOW
MAXIMUM LENGTH OF DUCT
30 feet (9.1 m)
HORIZONTAL EXHAUST INSTALLATION
AIR
FLOW
D753I
1 Roof
2 No Screen or Cap
3 Wall
4 2 in. (5 cm) Minimum
5 NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, an opening must
be sized as shown or per local codes.
3
1
4
5
24 in. (61 cm)
MINIMUM
CLEARANCE TO
ROOF/GROUND
CONNECT TO DRYER
VERTICAL EXHAUST INSTALLATION
2
To reduce the risk of fire and the
accumulation of combustion gases, DO NOT
exhaust dryer air into a window well, gas
vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building.
W045
WARNING