Appendix A: Technical Specifications
52
Environmental Specifications
Power Specifications
Input Supply Voltage - 100-240 VAC, 50 - 60 Hz
Safety and Electromagnetic Emissions Certifications
Table 11. Environmental Specifications
Operating Temperature 0° C to 50° C (32° F to 122° F)
Storage Temperature -20° C to 60° C (-4° F to 140° F)
Operating Humidity 5% to 80% non-condensing
Storage Humidity 5% to 95% non-condensing
Operating Altitude Range Up to 2,000 m (6,562 ft)
Table 12. Power Specifications
AT-GS908M 12 W
AT-GS916M 22 W
AT-GS924M 30 W
Table 13. Safety and Electromagnetic Emissions Certifications
RFI Emissions
FCC Part 15 Class A
CISPR Class A
EN55022:2006/A:2007 Class A
RCM
Immunity EN55024
Electrical Safety EN60950-1 (ULEU), UL 60950-1
(
C
UL
US
), CE
Environmental Compliance EU-RoHS compliant, WEEE
China RoHS compliant