Troubleshooting by Error Codes
Temperature Sensor Check
Disconnect the temperature sensor from PCB, measure the resistance value with a tester.
Temperature Sensors:
Room temperature (T1) sensor,
Indoor coil temperature(T2) sensor,
Outdoor coil temperature (T3) sensor,
Outdoor ambient temperature (T4) sensor,
Discharge temperature (T5) or (TP) sensor.
Measure the resistance value of each winding by using the multi-meter.
Compressor Checking
Measure the resistance value of each winding by using the tester
Figure 26. Input Terminal
Position Resistance Value
Model ASN98D22UFZ ASK89D29UEZD ASN140D21UFZ ATF235D22UMT
Blue - Red
1.57(20°C/68°F) 1.99(20°C/68°F) 1.28(20°C/68°F) 0.75(20°C/68°F)Blue - Black
Red - Blue
Table 15. Compressor Terminal Resistance