Translated from the original language - English - 43Manual 6-1624970M - rev. 1 - 11/01/2023
Function of Mechanical Relaxation
It allows you to perform a short reversal, the duration of which is customizable, once you reach the limit switch of opening or closing.
This function is useful in case automation presses the mechanical blocks too hard and makes manual unlocking dicult.
PARAMETER VALUES DEFAULT
MrE
OFF = Disabled.
From 1 to 20 multiplied by 100 ms
OFF
Function of Soft Stop
It allows to adjust the deceleration ramp in case of request of stop by user command or in case of intervention of the photocell
inputs (PH1 and PH2). This parameter DOES NOT modify the deceleration ramp in case of intervention of the EDGE (safety edge)
and STOP input.
PARAMETER VALUES DEFAULT
SFt
From 6 to 20 multiplied by 100 ms 10 = 1000 ms
Modbus Address
Address attribute to the control unit to establish a MODBUS communication.
PARAMETER VALUES DEFAULT
MbAdr
From 0 to 247 0 = OFF
Reset to the Default Values (RESET)
It performs a reset of the control unit and sets the values of all the basic and advanced parameters, bringing them to the default
ones.
This function DOES NOT cancel the learned run and DOES NOT erase the learned remotes.
To perform the reset follow below steps:
Access the parameter by holding the MENU button for 3 seconds.
When the display displays the value " 0 " release the button.
Press the MENU button and hold it until the countdown ends and the display displays " don ".
The procedure was successfully completed.
PARAMETER VALUES DEFAULT
dEF
0 = MAX 2200 Kg
1 = MAX 1200 Kg
2 = MAX 800 Kg
3 = MAX 500 Kg
0
Viewer memory location of a learned transmitter
With this parameter you can view the memory location assigned to a transmitter by the control unit during learning. To do this follow
the following steps:
Access the parameter by holding the MENU button for 3 seconds.
When the display displays the value " SEE " release the button.
From this moment, the control unit is waiting for a known radio command. WARNING: after 15 seconds without receiving any
transmission, the control unit automatically exits the function by displaying the message " tout ".
Transmit with your own remote control, the display will display the memory position (for example " 245 ").
More than one remote control can be displayed in the same session. To exit the function, briefly press the MENU button.
PARAMETER VALUES DEFAULT