Setup and connection
5 Setup and connection
For pumps in explosion-hazard areas (→ ATEX additional
instructions).
NOTE
Material damage d ue to distortion or passage of electrical
current in th e bearing!
Do not make any structural modifications to the pump unit
or pump casing.
Do not carry out any welding work o n the pump unit or
pump casing.
NOTE
Material damage caused by dirt!
Do not remove any covers or transport and screw plugs
until immediately before connecting the pipes to the pump.
5.1 Preparing the setup
5.1.1 Checking the ambient conditions
Make sure the required ambient conditions are fulfilled
(→ 9.2.1 Ambient conditions, Page 31).
5.1.2 Preparing the installat ion site
Ensure the installation site meets the following conditions:
– Pump is freely acce ssibl e from all sides
–Sufficient space for the installation/removal of the pipes
and for maintenance and repair work, especially for the
removal and installatio n of the pump a nd the motor
– Pump not exposed to external vibrations (damage to
bearings)
– Frost protection
5.1.3 P reparing the surface
Make sure the surface meets the following conditions:
–Level
– Clean (no oil, dust o r other impurities)
– Capable of bearing the weight of the pump unit and all
operating forces
– The pump is stable and cannot tip over
5.1.4 R emoving the preservative
If the pump is to be put into operation immediately after
setup an d connection: Remove the pres ervative prior to
setup (→ 4.4 Removing the preservative, Page 13).
5.1.5 Installing the heat insulation (optional)
Only necessary to maintain the temperature of the pumped
liquid.
NOTE
Material damage on the b earing o r shaft seal due to over -
heating!
Only install the heat insulation on the pump cas ing
(→ Figure Layout, Page 10).
Install the heat insulation properly.
5.2 Setup
If installing horizontally with lateral connections, the filling
and bleeding holes and the mano meter conne ctions must
face upward.
Setup options
• With wall-moun ted/foot-mounted moto r bracket
– horizontal, connections on top or sides
– vertical, motor at top
5.2.1 Setup with wall-mounted/foot-mounted
motor bracket
Pump units with wall-mounted/foot-mounted m otor bracket
can be install ed vertically (motor at the top) or horizontally.
1. Lift the pump unit and set it down at the installation location
(→ 4.1 Tra nsport, Page 12).
2. Install the pump unit (→ setup drawing).
14 SPF series BA-2014.01 626.0005 GB – 550 041