Centrifugal Pump with
Volute Casing
Original Operating Manual NIT series
Version BA-2017.03 en-US
ID-No. 550 154
160-282/0
ALLWEILER GmbH
Postfach 1140
Allweilerstr. 1
78301 Radolfzell
Germany
Phone: +49 (0) 7732-86-0
Fax: +49 (0) 7732-8 6-436
E-mail: service@allweiler.de
Internet: http://www.allweiler.com
We reserve the right to m ake technical changes.
Read carefully before use.
Save for future use.

Table of Contents

Questions and Answers

  • B
    Brandy DeleonOct 31, 2025
    What to do if my Allweiler Water Pump is not pumping?
    • N
      Neil McfarlandOct 31, 2025
      If your Allweiler Water Pump isn't pumping, several factors could be at play. Check if the supply/suction pipe and/or pressure pipe are blocked by the armature and open it. Ensure the supply/suction pipe is fully opened. Also, the stub shaft might be loose, so tighten it firmly. The supply/suction pipe, pump, or suction strainer could be blocked or encrusted, requiring cleaning. The supply/suction pipe cross-section might be too narrow, so increase it and remove any encrustations. If a transport and sealing cover is still in place, remove it and inspect the pump for dry-running damage. Ensure the supply/suction pipe is properly bled and completely filled, correcting the piping layout to eliminate air pockets. If air is being sucked in, seal the source of the malfunction. For excessive gas ...

Summary

About this document

Target Groups

Identifies the intended users of the manual and their roles.

Other Applicable Documents

Lists related documents essential for proper operation and safety.

Warnings and Symbols

Explains warning symbols and their meanings for safety.

Technical Terms

Defines key terminology used within the manual.

Safety

Intended Use

Specifies the correct and intended applications for the pump.

General Safety Instructions

Provides essential safety guidelines for operating the pump safely.

Specific Hazards

Addresses specific risks associated with pump operation.

Layout and Function

Labels

Describes identification plates and markings on the pump.

Pump Layout

Provides a diagram and explanation of the pump's physical components.

Shaft Seals

Discusses the function and types of mechanical seals used.

Auxiliary Systems

Describes additional systems connected to the pump.

Transport, Storage, and Disposal

Transport

Guidelines for safely transporting the pump unit.

Preservation

Instructions for preserving the pump during storage.

Storage Conditions

Recommended conditions for storing the pump to prevent damage.

Removing Preservative

Steps for safely removing protective preservatives.

Disposal

Guidelines for environmentally sound disposal of the pump.

Setup and Connection

Preparing the Setup

Initial steps and checks before setting up the pump.

Piping Planning

Crucial guidance for designing the pump's piping system.

Installing in the Pipe

Instructions for integrating the pump into the piping system.

Installing the Motor

Detailed procedure for mounting the motor onto the pump.

Electrical Connection

Critical steps for connecting the pump's electrical power supply.

Installing Coupling Guard

Procedure for fitting the safety guard for the coupling.

Performing Hydrostatic Test

Steps for conducting a hydrostatic pressure test on the pump.

Operation

Preparations for Initial Start-up

Crucial pre-operation checks and procedures.

Start-up Procedure

Step-by-step guide for safely starting the pump.

Shutting Down

General guidelines for shutting down the pump, including prolonged periods.

Start-up After Shutdown

Procedures for restarting the pump after it has been idle.

Operating Stand-by Pump

Instructions for the periodic operation of a stand-by pump.

Maintenance

Inspections

Guidelines for periodic checks and inspections of the pump.

Routine Maintenance

General maintenance tasks and considerations for the pump.

Dismounting

Instructions and safety precautions for disassembling the pump.

Installing Components

Steps for reassembling the pump after maintenance or repair.

Ordering Spare Parts

Information required when ordering replacement parts.

Troubleshooting

Appendix

Sectional Drawings

Visual representations of the pump's internal components.

Technical Specifications

Provides performance data and technical details for the pump.

Spare Parts Recommendation

Lists recommended spare parts for two years of operation per DIN 24296.

Declaration of Harmlessness

Form for declaring the harmlessness of returned pumps.

Declaration of Conformity

Official statement of compliance with EC Machine Directives.

Allweiler NIT Series Specifications

General IconGeneral
BrandAllweiler
ModelNIT Series
CategoryWater Pump
LanguageEnglish