Troubleshooting
Fault number
12 34
5
6
7
8
Cause
Remedy
–– ––
Lubricant: too mu ch, not enough or
unsuitable
Reduce, top up or re place the lubrican t.
––
X
Connecting b olts not tightened properly
Tighten the connecting b olts.
––
X
Mechanical seal worn
Replace the mechanical seal.
––
X
Housing seal d efective
Replace the housi ng seal.
––
X
Shaft sleeve is inltrated
Replace the shaft sleeve and/or O-ring.
––
XXXPumpdistorted
Check the pipe connections and pump
attachment.
X
X
X
X Motor running on 2 phases
Check the fuse and replace it if
necessary.
Check the cable connections and
insulation.
Tab. 13 Troubleshooting list