Table 7, Light On/O
Table 8, Light On+ Timer
Figure 14, Light On/O Working Time
Light On/O
Mode Function
Light On Voltage
(Night Threshold)
When the input voltage of the solar module is lower than the Light On voltage, the load output is turned
on automatically, given that the battery capacity is sucient and there are no abnormal conditions.
Light O Voltage
(Day Threshold)
When the input voltage of the solar module is higher than the Light O voltage, the load ouput is
automatically turned o.
Delay Time
During this period, if the light signal voltage continues to match the Light On/O voltage, it will carry out
any corresponding actions (Adjustment Range: 0~99min).
Light On+ Timer
Mode Function Whenever the working time
is set to 0, there will not be
a working period. The real
working time of T2 depends
upon the Night Time and the
length of T1 and T2.
Working Time 1(T1) The working period of the load after the light control turns on the load.
Working Time 2 (T2) The working period of the load before the light controls turns o the load.
Night Time Total calculated night time of the controller.
Light O
Dusk
Night Time
Dawn
Light O
Light On
Light On
Working Time 1 Working Time 2