No. Display Description Remedy
795 Undervoltage Undervoltage on inverter. Check the inverter voltage supply.
796 Safety switch o Safety Input was triggered.
Case 1: Inverter malfunction.
Reset automatically
Case 2: High-pressure pressostats in refrigerating circuit have
triggered
Reset automatically
Case 3: Only LWDV malfunction message caused by voltage
uctuations exceeding the valid standard.
Case 1: Check inverter.
Remedy fault.
Case 2: Check HW throughow, overow,
ow temperature sensor and high-
pressure sensor.
Remedy fault.
Case 3: It must be turned o and resecured
manually
797 MLRH is not supported Heating rod regulating is not supported. –
798 ModBus connection lost
Fan
No ModBus communication with the fan for at least 10
seconds. Reset automatically.
Check ModBus – Fan wiring
799 ModBus connection lost
ASB
No ModBus communication with the ASB board for at least 10
seconds. Reset automatically.
Check ModBus – ASB board wiring
800 Desuperheater-error Shutdown is triggered when desuperheater temperature
≥80 ° C. Device is switched o and D0_Pause is written in
shutdowns.
Device is released again for operation after 2 hours.
If the shutdown occurs 5 times within 24 hours, error 800 is
written to the fault memory.
Remove energy from desuperheater
memory.
The machine can be restarted as soon as
the temperature falls < 80°C.
801 HP oine The heating and heat pump controll does not have an
Internet connection has no internet connection to the remote
maintenance server.
Establish internet connection.
802 Temperature electrical
switch box
Shutdown will be triggered when temperature in the electrical
switch box ≥80°C. If the temperature falls below 70°C, then
the heat pump will start up again. Reset automatically.
Check fan for correct function.
Check connection cable. Check sensor.
Check electrical control box openings for
blockages.
803 Temperature electrical
switch box Blockage
Error 802 tripped 3 times within 24 hours. Manual reset
required. If the temperature in the electrical switch box is still
≥ 80°C, the error will be triggered again immediately.
Check fan for correct function.
Check connection cable. Check sensor.
Check electrical control box openings for
blockages.
804 Sensor temperature
electrical switch box
Sensor error electrical switch box temperature. Check sensor.
805 Sensor desuperheater Sensor error desuperheater temperature. Setting in the menu “FlexCong - Out2” is
set to “Enth” although this is not required.
Deselect “Enth”
Check sensor.
806 ModBus SEC The SEC-board has no ModBus communication for at least 10
seconds or query has failed 10 times in a row.
Reset automatically.
Check ModBus – SEC board wiring.
807 Lost ModBus
communication
All possible ModBus communication faults with unit compo-
nents for the respective unit are present simultaneously for at
least 10 seconds. Reset automatically.
Check ModBus interface on the control
unit, connection cable to ModBus
distributor and ModBus distributor itself.
Check Modbus wiring.
808 Hardware not supported Software version of the heating and heat pump controller is
incompatible with installed ASB hardware.
Carry out software update