EasyManuals Logo

Alpha-InnoTec SWP Series User Manual

Alpha-InnoTec SWP Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
We reserve the right to make technical changes.
UK830509/200114 © Alpha-InnoTec GmbH
Heat quantity recording
In addition to the proof of the unit’s efciency,
EEWaermeGalso meets the demand for a heat quantity
recording (hereafter refered to as HQR). The HQR
is mandatory with air/water heat pumps. With brine/
water and water/water heat pumps, a HQR may only be
set up when a forward ow temperature of 35 °C has
been reached. The HQR must record the total warm
energy release (heating and hot water) in the building. In
heat pumps with heat quantity recording, the analysis is
conducted by the regulator. The regulator displays the
thermal energy that is exchanged from the heating system
in kWh.
Operation
Your decision to opt for a heat pump or heat pump sys-
tem means you can now make a contribution to sparing
the environment over many years thanks to low emis-
sions and lower primary energy use.
You operate and control the heat pump system via the
control panel of the heating and heat pump control.
NOTE.
Ensure that the control settings are cor-
rect.
Operating instructions for the heat and heat
pump control.
To ensure that your heat pump or heat pump system op-
erates efciently and ecologically, the following are espe-
cially important:
ENERGY SAVING TIP
Avoid unnecessarily high ow tempera-
tures.
A lower ow temperature on the hot wa-
ter side increases the efciency of the sys-
tem.
ENERGY SAVING TIP
When letting in fresh air, do not leave win-
dows open for an extended period in or-
der to save energy and reduce your heat-
ing costs.
Care of the device
You can clean the surface of the device exterior with a
damp cloth and standard cleaning agents.
Do not use cleaning and care agents which scour or
which contain acid and/or chlorine. Media of this type
would irreversibly damage the surfaces and possibly
cause technical damage to the device.
Device maintenance
The cooling circuit does not require any regular mainte-
nance.
According to EU regulation (EC) 842/2006 of May 17,
2006, leak inspections and maintenance of a log book
are required by law for certain heat pumps!
The criteria for conducting leak inspections and
maintaining a log book are based on the hermetic
impermeability of the cooling circuit and the refrigerant
capacity of the heat pump! No log book is required for
heat pumps with a refrigerant capacity of < 3kg. With all
other heat pumps, the log book is included with all other
delivered materials.
Log book for heat pumps, Section Information
on use of the log book.
The components of the heating circuit and the heat
source (valves, expansion vessels, circulating pumps,
lters, dirt traps) should be inspected as well as cleaned
as needed - at the very least annually - by a qualied
heating or cooling system technician.
The best solution is to conclude a service agreement
with a heating installation company. This will carry out
all the required maintenance work at regular intervals.
Cleaning and Rinsing of deviCe Components
CAUTION!
Only customer service personnel author-
ised by the manufacturer may clean and
rinse device components. Only liquids rec-
ommended by the manufacturer may be
used for this.
After rinsing the condenser with chem-
ical cleaning agents, a neutralisation of
residues and intensive rinsing with water
will be necessary. When doing so, observe
the technical data of the relevant heat ex-
changer manufacturer.

Table of Contents

Other manuals for Alpha-InnoTec SWP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec SWP Series and is the answer not in the manual?

Alpha-InnoTec SWP Series Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelSWP Series
CategoryHeat Pump
LanguageEnglish

Related product manuals