F5# Program startdate of summer/wintertime code level 4, 5 or 6
F6# Program usercodes code level 5
F7# Start programming at PC for installer code level 6
F8# Call the 9th telephone number for up/downloading code level 5
F9# Display historical overview on keypad code level 4, 5 or 6
F10# Print historical overview via printermodule code level 4, 5 or 6
F11# Turn logprinter function on/off code level 4, 5 or 6
F12# Print RTC overview via printermodule code level 5 or 6
F13# Print user code overview via printermodule code level 5
F14# Print first part of installation overview via printermodule code level 6
F15# Print second part of installation overview via printermodule code level 6
F16# Test outputs code level 5 or 6
F17# Test batteries of control panel and I/O modules code level 4, 5 or 6
F18# Test LCD and LED's of the keypad code level 5 or 6
F19# Test zones 01 through 96 code level 6
F20# Walktest zones code level 6
F21# Display open zones all code levels
F22# Display available information code level 4, 5 or 6
F23# Program RTC disarming / arming time schedule code level 5
F24# Program RTC overtime function code level 4 or 5
F25# Program RTC vacation schedule code level 5
F26# Program RTC correction factor code level 5 or 6
F27# Maintenance mode code level 6
F28# Program inputs code level 6
F29# Program NG Proximity Readers code level 6
Bxx#
*
Bypass zones code level 4 or 5
*
<]> key followed by zonenumber (xx) followed by <#>
User codes can be programmed and changed on the keypad, with a PC or from a remote site.
Program user codes with the PC
Option 3 of the main menu is titled “Program user codes”. When you select this option the screen will
change to:
Enter main user code (4-6 digits)followed by ENTER:
Now enter the main user code (98th code), followed by <ENTER>. When the correct code is entered, the
following screen will appear:
INSTALLATIONS DATA: ALPHAVISION NG v1.1 -- date
NR. NAME CODE LEV. SECTION SMTWTFS
001 AAAA 000000 0 xxxxxxxx xxxxxxx
002 AAAA 000000 0 xxxxxxxx xxxxxxx
003 AAAA 000000 0 xxxxxxxx xxxxxxx
004 AAAA 000000 0 xxxxxxxx xxxxxxx
005 AAAA 000000 0 xxxxxxxx xxxxxxx
006 AAAA 000000 0 xxxxxxxx xxxxxxx
007 AAAA 000000 0 xxxxxxxx xxxxxxx
008 AAAA 000000 0 xxxxxxxx xxxxxxx
009 AAAA 000000 0 xxxxxxxx xxxxxxx
010 AAAA 000000 0 xxxxxxxx xxxxxxx
011 AAAA 000000 0 xxxxxxxx xxxxxxx
012 AAAA 000000 0 xxxxxxxx xxxxxxx
013 AAAA 000000 0 xxxxxxxx xxxxxxx
014 AAAA 000000 0 xxxxxxxx xxxxxxx
015 AAAA 000000 0 xxxxxxxx xxxxxxx
016 AAAA 000000 0 xxxxxxxx xxxxxxx
017 AAAA 000000 0 xxxxxxxx xxxxxxx
AlphaVision NG installation manual Rev. 2.0 27-08-2003 Blz. 57/101
018 AAAA 000000 0 xxxxxxxx xxxxxxx

Table of Contents