NGPR2 OC output
0: not used
Now enter the desired function (0, 1, 2 or 3) of the Open Collector output of the Proximity Reader. This OC
output can function in one of the following ways:
Programming: Function:
0 Not used
1 Dooropener
2 Entry/ Exit buzzer
3 Valid TAG
Press the <#> key when the desired option is shown in the display. Then press the <> key to continue to the
features programming. The display will change to:
NG Prox Reader 2
features
Press the <#> key. The display will change to:
NGPR2 triggers
entrytime? NO
When this is the desired programming, press the <#> key. When this must be changed to YES, press the <>
key. The display will change to:
NGPR2 starts
entrytime? Yes
Now press the <#> key to accept the current programming. The display will change to:
NGPR2 lastdoor
function? NO
When NO must be changed to YES, press the <> key. Then press the <#> key to accept the current
programming. The display will change to:
NGPR2 logreport
in his.ovv.? NO
When NO must be changed to YES, press the <> key. Then press the <#> key to accept the current
programming. The display will change to:
NGPR2 logreport
on printer? NO
When NO must be changed to YES, press the <> key. Then press the <#> key to accept the current
programming. The display will change to:
LCD/PROX activate
RO modules? NO