29
Sanitize/Clean-up Cycle
Thesanitizebuttonactivatesa20minutesanitisationcyclethatrunstheltration
pumpandozone/U.Vtolterthespapoolwatertorestoreandrefreshwater
quality.Atthestartandendofthecycle,thecontrollerwillsequentially(oneata
time)runavarietyofpumpsforoneminuteeachtopurgetheplumbingandclear
anyunlteredwatertrappedinthoselines.
Key-lock Function
Thekeypadbuttonscanbelockedtopreventaccidentalkeypressesortolimit
accesstocertaincontrollerfunctions.Thisfeatureisparticularlyhelpfulwhenspa
poolcoversareusedorwherechildrenarepresent.
Therearetwotypesofkey-locksavailable:
FullLockMode-locksallbuttonssoallpressesareineffectiveuntilunlocked.
Toactivatefulllock,pressandholdtogether:
Automatic Daily Sanitise Cycle Run Time
Thesystemwillactivatea10minutedailysanitisationcycleat9ameachday.
Eachpumpisoperatedtopurgepipeworkwhilstoperatingtheltrationpump.
PartialLockMode-only‘PUMPS’,‘LIGHT’and‘SANITIZE’buttonsallowed.To
activatepartiallock,pressandholdtogether:
+
+
+
+
UP
UP
DOWN
DOWN
PUMP A
PUMP B
NOTE: Tounlock,repeatthesequence.PumpsarelabeledA,B,Cfromleft
torightonthecontrolpanel.Aspamodelwithoutaphysical‘pumpb’willstill
havea‘ghostbutton’where‘pumpb’wouldbelocatedandcanstillbepressed
toactivatethepartiallock.
AfullSpaNetcontrolpanelmanualwithadvancedfunctionscanbe
downloadedfromoursupportpage:http://alpinespas.co.nz/support/