INSTALLATION
Converge® Operator’s Manual MN-47239 Rev 3 5/23
27
Continued from previous page
It is the responsibility of the operator to make sure the incoming water supply is
tested and meets the compliance requirements with the published water quality
standards listed below. Non-compliance could damage the oven and void the
warranty. Alto-Shaam recommends using OptiPure products to treat the water.
Installing the water
supply
To install the water supply, do the following.
Step Action
1. Flush the water line at the installation site.
2. Install adequate backflow protection to comply with applicable federal, state,
and local codes.
3. Remove the two adapter fittings on the water inlets.
Continued on next page
Contaminant Treated Water Untreated Water
Free Chlorine less than 0.1 ppm (mg/L) less than 0.1 ppm (mg/L)
Hardness 30–70 ppm 30–70 ppm
Chloride less than 30 ppm (mg/L) less than 30 ppm (mg/L)
pH 7.0–8.5 7.0–8.5
Silica less than 12 ppm (mg/L) less than 12 ppm (mg/L)
Total Dissolved Solids (TDS) 50–125 ppm 50–360 ppm