How to Calibrate the Temperature Probe
Before you begin Make sure:
The oven is on, but not in cooking mode.
You have a thermometer.
You have a container filled with ice and water.
Procedure To calibrate the probe, do the following.
Step Action
1. Insert the probe and the thermometer in a container of ice water and allow
the temperature to settle to 32°F (0°C).
2. Touch the menu icon /. The menu screen displays.
3. Touch the “HACCP Data” icon 0. The “HACCP Data” screen displays.
Continued on next page
CT-TS-013849
a
CT-TS-013897
b