MAINTENANCE
Prodigi™ Operator’s Manual MN-47965 Rev 1 5/23
100
Continued from previous page
Inspect the oven cavity for any signs of scale buildup.
Inspect the ventless hood paper filter (if ventless hood is equipped, replace as
needed).
Test the ventless hood drain for proper drainage and signs of leaking.
De-scale as needed. See topic How to Descale the Oven.
Yearly For yearly maintenance, do the following.
Replace the steam bypass hose.
Inspect and test the humidity control.
Inspect all drain hoses and clamps.
Inspect all steam water injection lines and clamps for leaks or potential issues.
Inspect wiring to heating elements. Re-tighten or secure as needed. Record the
amp draw.
Inspect the cleaning system pump and hoses for leaks and proper operation.
Inspect and test the proper draining of the oven cavity.
Inspect the upper browning valve hose.
Inspect the low pressure relief valve and hose.
Inspect the convection element seal from the electrical compartment.
Inspect the gas heat exchanger seal from the electrical compartment.
Inspect the N6 oven temperature probe seal.
Inspect the hand shower handle and hose.
Check operation of all electrical cooling fans.
Test steam injection solenoid.
Test condensate solenoid.
Check all electrical connections are properly connected and secure to the
boards.
Check door hinges and handles. Tighten, secure, or adjust as needed.
Check door gaskets for damage and seal.
Run the oven in convection mode and test operation.
Run the oven in steam mode and test operation.
De-scale as needed.
NOTE: Must be performed by a qualified professional.