MAINTENANCE
Prodigi™ ▪ Operator’s Manual ▪ MN-47965 ▪ Rev 1 ▪ 5/23
100
Continued from previous page
▪ Inspect the oven cavity for any signs of scale buildup.
▪ Inspect the ventless hood paper filter (if ventless hood is equipped, replace as
needed).
▪ Test the ventless hood drain for proper drainage and signs of leaking.
▪ De-scale as needed. See topic How to Descale the Oven.
Yearly For yearly maintenance, do the following.
▪ Replace the steam bypass hose.
▪ Inspect and test the humidity control.
▪ Inspect all drain hoses and clamps.
▪ Inspect all steam water injection lines and clamps for leaks or potential issues.
▪ Inspect wiring to heating elements. Re-tighten or secure as needed. Record the
amp draw.
▪ Inspect the cleaning system pump and hoses for leaks and proper operation.
▪ Inspect and test the proper draining of the oven cavity.
▪ Inspect the upper browning valve hose.
▪ Inspect the low pressure relief valve and hose.
▪ Inspect the convection element seal from the electrical compartment.
▪ Inspect the gas heat exchanger seal from the electrical compartment.
▪ Inspect the N6 oven temperature probe seal.
▪ Inspect the hand shower handle and hose.
▪ Check operation of all electrical cooling fans.
▪ Test steam injection solenoid.
▪ Test condensate solenoid.
▪ Check all electrical connections are properly connected and secure to the
boards.
▪ Check door hinges and handles. Tighten, secure, or adjust as needed.
▪ Check door gaskets for damage and seal.
▪ Run the oven in convection mode and test operation.
▪ Run the oven in steam mode and test operation.
▪ De-scale as needed.
NOTE: Must be performed by a qualified professional.