EasyManua.ls Logo

Alto-Shaam Prodigi 6-10E Pro

Alto-Shaam Prodigi 6-10E Pro
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
Prodigi™ Operator’s Manual MN-47965 Rev 1 5/23
96
How to Calibrate the Temperature Probe
Before you begin Make sure:
The oven is on, but not in cooking mode.
You have a thermometer.
You have a container filled with ice and water.
Procedure To calibrate the probe, do the following.
Step Action
1. Insert the probe and the thermometer in a container of ice water and allow
the temperature to settle to 32°F (0°C).
2. Touch the menu icon /. The menu screen displays.
3. Touch the “HACCP Data” icon 0. The “HACCP Data” screen displays.
Continued on next page
CT-TS-014429
a
CT-TS-015910
b

Table of Contents

Related product manuals