OPERATION
Prodigi™ Operator’s Manual MN-47965 Rev 1 5/23
97
Continued from previous page
4. Touch the calibrate probes icon 1.
5. Compare the probe temperature reading against 32°F (0°C).
Touch the “+” or “–” symbols 2 until the temperature displayed is
32°F (0°C).
6. Remove the probe from the ice water.
Result The probe is now calibrated.
CT-TS-015913
c
CT-TS-015916
XX°
d