Using the machine
UF02 BAG00225.3 09.22
143
WARNING
Danger for people and animals from accidental contact with
spray liquid while filling of the spray liquid tank is underway.
Wear personal protective equipment when handling crop protec-
tion agent / dumping spray liquid from the spray liquid tank. The
type of personal protective equipment required depends on the
manufacturer's instructions, the product information, the direc-
tions for use, the safety datasheet or the user manual for the
crop protection agent in question.
Never leave the field sprayer unattended during filling.
Never fill the spray liquid tank beyond the nominal volume.
When filling the spray liquid tank, never exceed the permis-
sible load of the field sprayer. Pay attention to the respec-
tive specific weight of the liquid in question.
During filling, always watch the fill level indicator to avoid
overfilling the spray liquid tank.
Pay particular attention while filling the spray liquid tank to
sealed surfaces; no spray liquid may be allowed to get into
the sewerage system.
Check the field sprayer before each filling for damage, e.g. for
leaking tanks and hoses, as well as for the correct positioning of
all control elements.
During filling, pay attention to the permissible load capacity for your
field sprayer. Always take into account, when filling your field sprayer,
the differing specific weights [kg/l] for individual liquids.
Specific weights of different liquids
Liquid Water Urea AUS NP solution
Density [kg/l] 1 1.11 1.28 1.38
Control terminal:
In the control terminal, call up the filling display from the Job menu.
TwinTerminal:
Perform working by using the TwinTerminal on the control panel .
Control terminal ISOBUS:
Perform with the control terminal during operating the implement on
the field.