Formula and answer to Question 1:
Refill amount of water [l] x Concentration [%]
=
Addition of agent [l or kg]
100
(1,200 – 200) [l] x 0.15 [%]
=
1.5 [l or kg]
100
Formula and answer to Question 2:
Quantity of liquid available [l] – Residue [l]
=
Area to be treated [ha]
Water consumption [l/ha]
1,200 [l] (Tank nominal volume) – 20 [l] (Residue)
=
2.36 [ha]
500 [l/ha] Water consumption
11.2.2 Filling table for remaining spray area
The specified re-fill quantities apply for an application rate of 100
l/ha. For other application rates, the re-fill quantity increases by a
multiple.
Take account of the residual quantity in the boom.
Dis-
tance
Working width [m]
15 16 18 20 21 24 27 28 30 32 33 36 39 40
[m]
Re-fill quantities [l]
10
2 2 2 2 2 2 3 3 3 3 3 4 4 4
20
3 3 4 4 4 5 5 6 6 6 7 7 8 8
30
5 5 5 6 6 7 8 8 9 10 10 11 11 12
40
6 7 7 8 8 10 11 11 12 13 13 14 15 16
50
8 8 9 10 11 12 14 14 15 16 17 18 19 20
60
9 10 11 12 13 14 16 17 18 19 20 22 23 24
70
11 11 13 14 15 17 19 20 21 22 23 25 27 28
80
12 13 14 16 17 19 22 22 24 26 26 29 30 32
90
14 15 16 18 19 22 24 25 27 29 30 32 34 36
100
15 16 18 20 21 24 27 28 30 32 33 36 38 40
200
30 32 36 40 42 48 54 56 60 64 66 72 74 80
300
45 48 54 60 63 72 81 84 90 96 99 108 114 120
400
60 64 72 80 84 96 108 112 120 128 132 144 152 160
500
75 80 90 100 105 120 135 140 150 160 165 180 190 200