37
OPTIONAL FEATURE TABLE
OPTIONAL FEATURE TABLE
Feature
No.
Description Setting No.
01 Sensor Selection 00=Internal air sensor (Default)
01=Remote air sensor
02=Remote floor sensor
03=Internal air and remote floor sensor
04=Remote air and remote floor sensor
02 Time Format 12=12 hour, 24=24 hour (default)
03 Temperature Format 00=
o
C (Default), 01=
o
F
04 Frost Protection when off 00=Enabled (Default) 01=Disabled
05 Program Mode 00=Non Programmable
01=5/2 day programmable (Default)
02=7 day programmable
06 On/Off Status 00=Off when powered up
01=On when powered up
02=Auto memory when power lost
(Default)
07 Temperature Calibration -10
o
C ~ +10
o
C (-18
o
F ~ +18
o
F) (Default =0)
08 Switching Differential 1
o
C ~ 3
o
C (2
o
F ~ 5
o
F) (Default =1
o
C)
09 Maximum Temperature 2
o
C ~ 49.5
o
C (36
o
F ~ 121
o
F)
(Default =35
o
C)
10 Minimum Temperature 0
o
C ~ 47.5
o
C (32
o
F ~ 117
o
F) (Default =5
o
C)
11 Output Delay 00 ~ 15 minutes (Default = 00)