46. PRESENT MONTH        
The current month (1 to 12) 
  
47. PRESENT DATE       
The current day of the month (1 to 31). 
 
48. PRESENT YEAR         
The current year 
(00 to  99). 
 
49. MULTICELL MODE      
Enables the automatic cell selection mode of      
operation for the charger.  When turned off, the 
charger operates at the Fixed cell size (see FIX. 
CELL SIZE).                   
 
50. COOL DOWN HOURS 
The number of hours cool down from the end of 
charge until charge complete is indicated by the 
charger (0 to 8). 
 
51. BID CELLS         
If a connected battery is equipped with a Battery I.D. 
module, the battery cells size (6,9,12,18,24,36) may 
be reprogrammed into the BID. The control must be 
in ―Manual Stop‖ status. 
 
52. BID NUMBER        
If a connected battery is equipped with a Battery I.D. 
module, the I.D. number (001-999) may be re- 
programmed into the BID. The control must be in 
―Manual Stop‖ status. 
 
53. BID AMP HOURS   
If a connected battery is equipped with a Battery I.D. 
module, the battery amp-hour size (0000-9999) may 
be reprogrammed into the BID.  The control must be 
in ―Manual Stop‖ status. 
 
54. BID BATTERY TYPE     
If a connected battery is equipped with a Battery I.D. 
module, the battery type may be programmed into 
the BID.  The control must be in ―Manual Stop‖ 
status. 
    
 00    FLD      Flooded Lead Acid 
 01    CTM      Custom curve (programmable) 
 02    YGR      Sealed battery curve 
 03    SLR       Sealed battery curve 
 04    DSG      Sealed battery curve 
 05    SLE       Sealed battery curve 
 06    DAG      Sealed battery curve 
 07    CDR      Sealed battery curve 
  
 
55. PASSWORD     
Optional password required to program if turned on. 
  
   
56. NO GASSING HOURS      
The number of Hours before the charger can begin 
the gassing portion of the charging cycle.  (0 – 8 
Hours)  Not Available on the Standard Eclipse II 
Charger 
      
57. MAX BATT TEMP      
The maximum battery temperature for charging to 
start or continue.  Once interrupted, the charge will  
restart after the temperature drops 5 degrees F  
below the trip point. (For use with BID only) 
 
 58. BID START AMPS    
 Programs the charger start rate at the programmed  
 BID AH rating to the selected amps/100AH.  For  
 example, to charge an 800AH battery at 320 amps, 
 the ―BID Start Amps‖ would be programmed to 
 40A/100AH.  Please note that if the programmed rate 
 exceeds the maximum rated charger amps, the 
 charger output will be limited to the maximum current 
 rating.  Not Available on the Standard Eclipse II 
 Charger. 
 
 59. BATTERY CHARGE AMP HOURS  
 The accumulated amp hours charged into the battery.  
 An Amp Hour Accumulator and BID module assembly  
 must be installed on the battery to use this function. 
 The Amp Hour Accumulator continually records this 
 data while it is installed on the battery. 
  
 The data is automatically read from the bid when the  
 control terminates each charge cycle, except for  
 Manual Stop.  The data is stamped with the date and  
 BID number.  
 
 60. BATTERY DISCHARGE AMP HOURS  
 The accumulated amp hours discharged from the  
 battery.  An Amp Hour Accumulator and BID module 
 assembly must be installed on the battery to use this  
 function. The Amp Hour Accumulator / BID continually 
 records this data while it is installed on the battery. 
 
 The data is automatically read from the bid when the 
 control terminates each charge cycle, except for  
 Manual Stop. The data is stamped with the date and  
 BID number.  
 
 61. LONG TERM AVERAGE BATTERY  
 TEMPERATURE  
 The average BID temperature of the battery. An Amp  
 Hour Accumulator and BID module assembly must be  
 installed on the battery to use this function.  The BID  
 continually updates the average while it is installed on 
 the battery.    
7-10                                    September 30, 
193111-095 
EC2000 CONTROL FEATURES