Specifications
A-2 TM-F2OP-C1XN-01
Electrical Specifications
These specifications are warranted over a temperature range of 0 °C to
50 °C.
Nominal ambient temperature assumed is 25 °C.
Nominal line voltage is 208 Vac, 60 Hz.
See Table A-1 and Table A-2 for maximum values for model-dependent
specifications.
Specifications are subject to change without notice.
Table A-1
Specifications for 7.5 V to 40 V Models
Models 7.5-300 12-220 20-130 33-85 40-70
Output Ratings:
Output Voltage
a
Output Current
b
Output Power
0-7.5 V
0-300 A
2250 W
0-12 V
0-220 A
2640 W
0-20 V
0-130 A
2600 W
0-33 V
0-85 A
2805 W
0-40 V
0-70 A
2800 W
Line Regulation:
c
Voltage (0.01% of Vmax +
2mV)
Current (0.01% of Imax + 2 mA)
2.75 mV
32 mA
3.2 mV
24 mA
4mV
15 mA
5.3 mV
10.5 mA
6mV
9mA
Load Regulation:
d
Voltage (0.02% of Vmax +
5mV)
Current (0.02% of Imax + 5 mA)
6.5 mV
65 mA
7.4 mV
49 mA
9mV
31 mA
11.6 mV
22 mA
13 mV
19 mA
Meter Accuracy:
Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)
0.09 V
4A
0.13 V
2.3 A
0.3 V
1.4 A
0.43 V
0.95 A
0.5 V
0.8 A
Output Noise (0-20 MHz):
Voltage (p-p) 100 mV 100 mV 100 mV 100 mV 150 mV
Output Ripple (rms):
Voltage
Current
e
10 mV
1600 mA
10 mV
1200 mA
10 mV
400 mA
15 mV
300 mA
15 mV
200 mA
Drift (30 minutes):
f
Voltage (0.07% of Vmax)
Current (0.7% of Imax)
For Resistive Programming:
Voltage (0.6% of Vmax)
Current (0.6% of Imax)
3.75 mV
2100 mA
45 mV
1800 mA
6mV
1540 mA
72 mV
1320 mA
10 mV
910 mA
120 mV
780 mA
16.5 mV
595 mA
198 mV
510 mA
20 mV
490 mA
240 mV
420 mA